Reach Out To Us: (631) 595-9300

sales@solventsco.com

Solvent Cleaning and Vapor Degreasing

Solvent Cleaning & Vapor Degreasing

Using a solvent system (either in liquid or vapor forms) to remove soil from a surface of a substance  requires the knowledge of how the solvent interacts with the soil, affects the surface, and which solvent can do it better while considering other factors such as the environmental impact, safety of the workplace, efficiency of the process and cost.

 
Light Duty
Medium Duty
Heavy Duty
Cleaning Degreasing
Versatill®
Versatill®
Versatill®
FLO™
Solvon®
Properties
Unit
P
PE
L
LE
LC
LCa
SG35i
QP5
QP5i
SG65i
ZT
ZTe
PB
IP
AER
Consist of HFEHFE, AOHHFEHFE, AOHtDCE, HFEtDCE, HFE, AlcoholtDCE, HFC AlcoholtDCE, HFEtDCE, HFE, AlcoholtDCE, HFC AlcoholtDCE, HFCtDCE, HFC, AlcoholnPBnPB, AlcoholnPB
Boiling Point°C939151503938364848364645706871
Flash Point°CNoneNoneNoneNoneNoneNoneNonenonenoneNonenonenonenonenonenone
Vapor PressurekPA91236385153674745674647.514.714.414.1
Heat of VaporizationkJ/kg122132172175192205254235240254271279246246246
Liquid Densityg/cm³1.531.491.381.321.321.311.221.291.261.221.281.261.321.231.33
Kinematic ViscositycSt0.430.430.330.330.330.320.320.320.320.320.320.310.370.370.37
Specific HeatJ/kg-K123011901333126013101302131010851072131010901125113011301130
Surface TensionmN/m13.7121513.215.116.2181919182121242124
Kauri-butanol valueKb1012101233383810910877106119125150125
Dielectric StrengthkV>25>15>25>15>25>25>25>35>35>25>35>35>25>25>25
Global Warming PotentialGWP6157272513121453327524240.50.50.5
Ozone Depletion PotentialODP0000000000000.00490.00420.0049
Exposure Guidelinesppm200200500500>200>200>200200200>200194190252525
Replacement for
CFCs
HCFCs
HFCs    
TCEs    
HFEs        
nPB       
Aqueous
Effectively Removes Soils
Light Oils
Medium Oils    
Fluoro Lubes         
Particulates    
Ionic Soils       
Greases    
Fluoro Greases       
Silicones    
Fluoro Silicones           
Flux    
Wax    
Solubility
FluorocarbonHighHighHighHighMediumMediumMediumLowLowLowLowLowLowLowLow
HydrocarbonMediumMediumMediumMediumHighHighHighHighHighHighHighHighHighHighHigh
SiliconeLowLowLowLowMediumMediumMediumHighHighHighHighHighHighHighHigh
Compatibility
PlasticsRequires Individual TestingRequires Individual TestingRequires Individual TestingRequires Individual Testing
Acrylics, ABS, PolycarbonateHighHighHighHighNoneNoneNoneNoneNoneNoneNoneNoneNoneNoneNone
PTFE, PEEK, Nylon, epoxyHighHighHighHighHighHighHighHighHighHighHighHighHighHighHigh
SiliconesMediumMediumMediumMediumLowLowMediumLowLowLowLowLowLowLowLow
CeramicsHighHighHighHighHighHighHighHighHighHighHighHighHighHighHigh
MetalsHighHighHighHighHighHighHighHighHighHighHighHighHighHighHigh
Percision Cleaning Application
Co-Solvent           
Vapor Degreasing
Immersion
Hand-Wipe   
Spray Cleaning   
  • Not for specification purposes. All values @ 25°C unless otherwise specified.
  • Values gathered from public sources or calculated based on available data.
  • GWP-100 year ITH, CO₂ = 1.0
  • Trade marks are the property of their respective owners.